Hitachi
J300 Series Inverter (Legacy Product)
The Hitachi
J300 auto tuning sensorless flux vector inverter has features never before
achieved in a drive of its type.
The Hitachi
J300 enables performance approaching that of a servo system, at low cost,
with easy installation and setting, yet with features which benefit the
broadest cross section of industries. The drive can be fitted to almost
any AC motor and appeals equally to OEMs and end users.
The J300
takes this technology on a generation with the application of fuzzy logic
and the incorporation
of advanced features such as automatic tuning. Indeed, both the range
of features and mechanical construction of the J300 is indicative of Hitachi's
total design approach. Hitachi's sensorless flux vector inverters give
approaching AC servo performance from a drive that is as easy to install
as any open loop system.
The J300
is a dual rated inverter allowing a variable torque load to use the inverter
size below. Helping
to reduce the cost of an installation.
| J300 |
400V
Series |
| Model
Number |
055
HFE |
075
HFE |
110
HFE |
150
HFE |
220 HFE |
300 HFE |
| Motor
Power (kW) - CT |
5.5 |
7.5 |
11.0 |
15.0 |
22.0 |
30.0 |
| Motor
Power (kW) - VT |
7.5 |
11.0 |
15.0 |
22.0 |
30.0 |
37.0 |
| Input
Supply Phase |
Three
Phase |
| Rated
Input Voltage |
380Vac
~ 480Vac ± 10%, 50/60Hz ± 5% |
| Rated
Output Voltage |
Three
Phase 380V ~ 480Vac
(Corresponds to input voltage) |
| Rated
Output Current (A) - CT |
13 |
16 |
23 |
32 |
48 |
58 |
| Rated
Output Current (A) - VT |
16 |
23 |
30 |
44 |
59 |
74 |
| Dimensions
W/H/D in mm |
220/340/195 |
250/440/220 |
300/450/250 |
390/620/330 |
| J300 |
400V
Series |
| Model
Number |
370 HFE |
450
HFE |
550
HFE |
750
HFE |
900
HFE |
1100 HFE |
| Motor
Power (kW) - CT |
37.0 |
45.0 |
55.0 |
75.0 |
90.0 |
110.0 |
| Motor
Power (kW) - VT |
45.0 |
55.0 |
75.0 |
90.0 |
110.0 |
132.0 |
| Input
Supply Phase |
Three
Phase |
| Rated
Input Voltage |
380Vac
~ 480Vac ± 10%, 50/60Hz ± 5% |
| Rated
Output Voltage |
Three
Phase 380V ~ 480Vac
(Corresponds to input voltage) |
| Rated
Output Current (A) - CT |
75 |
90 |
110 |
149 |
176 |
217 |
| Rated
Output Current (A) - VT |
88 |
108 |
146 |
176 |
217 |
260 |
| Dimensions
W/H/D in mm |
390/620/330 |
480/700/330 |
480/700/270 |
550/780/270 |
J300 Service
Manual
|