AC Servo Terminal Connection


200V Class

Note 1: For single phase input AC 220 to 230V drive, Only use L1 and L2. (No connection with L3)
  2: A battery is used only for the absolute encoder.
  3: The regenerative braking resistor is built-in the drive for 400W to 750W. In case of insufficient braking capacity, remove the short bar between B1 and B2. Connect the external braking resistor between RB and (+).

400V Class

Note 1: Connect three phase 380 to 480V to L1, L2 and L3, and single phase 200 to 240V to L1C and L2C. Do not input 380 to 480V to L1C and L2C. Make sure when using a transformer that the secondary is 200 to 240V.
  2: In case of insufficient braking capacity, remove the short bar between B1 and RB. Connect the external braking resistor between RB and (+).
  3: Earth Connection ()